Showing posts with label Virtualized SBS. Show all posts
Showing posts with label Virtualized SBS. Show all posts

Thursday, 28 July 2011

iSCSI Initiator – Driver Causes Spontaneous Reboots BSOD STOP 0x0000000a

When things went sideways with the iSCSI Software Target setup yesterday our SBS 2011 VM started to spontaneously BSOD on a 0x0000000a.

When it started to happen the first place we checked when we logged in was the MiniDump folder since the server was set to create one.

image

Unfortunately, the first run through with the Crash Dump Analyzer (part of Windows Desktop Software Assurance MDOP) the result was misinterpreted by myself.

So, as can be seen by the above, the server went through a few BSOD and reboot cycles before it sunk in that the problem was with iSCSI Initiator and _not_ the Hyper-V SCSI bus. :(

image

image

Once we managed to get into the iSCSI Initiator’s control panel and disconnect the missing iSCSI target and drive we regained stability.

Chalk the miss up to not taking a step back, taking a deep breath or ten, and then subsequently looking at the situation again with fresh eyes . . . which was done a bit later. ;)

Moral of the story: Make sure that the iSCSI attached backup destinations are _offline_ in Disk Management on the VM before making any changes at the iSCSI Software Target server.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Monday, 27 June 2011

Promise VTrak– RAID Migration Time To Add Two 300GB 15K SAS Drives To Existing Disk Array

The Promise VTrak E610sD unit that we have been using for our IMS and Intel Server System based Hyper-V failover clustering had eight (8) 300GB 15K Seagate SAS drives configured in one Disk Array.

We added two more 300GB 15K Seagate SAS drives to the VTrak unit to test how a live RAID Migration would impact overall performance of the unit.

image

Event 42: DA_0 – June 24, 2011 1335Hours – RAID migration has started.

We had the VMs on the cluster shut down initially to bring all disk activity as close to zero MB/Second as possible.

When we went through the RAID Migration steps we made a point of preserving the VM’s LUN RAID 10 configuration as it wanted to change the configuration to RAID 1E.

image

Once we clicked Next, Submit, and Confirmed that we wanted the RAID Array Migration to run we saw the following:

image

That 0% sat there _for a long time_.

Meanwhile, with the VMs shut down we saw:

image

Based on that 28MB/Second number we figured that the RAID Array Migration process was going to take a while.

Well, it most certainly did:

image

Event 46: DA_0 – June 25, 2011 1159Hours – RAID migration has completed.

The process took around 22.5 Hours!

Now, we did fire up the four VMs running on the Hyper-V cluster not long after the above performance graphs snip was taken. So, we had SBS, SQL with LoB, and two Windows 7 desktop VMs running in production mode while the migration was happening.

We did some performance testing in the LoB as we had already been running some baseline performance tests for the cluster setting and saw very little if any impact on its performance.

The LoB is SQL, IIS, and .NET intensive.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Saturday, 18 June 2011

HP P2V – Make Sure to Stop and Disable HP Services

The SBS and SQL servers we restored to our newly created 2 node Hyper-V cluster were originally installed on HP hardware.

Once the P2V process using the native Windows Server Backup to restore to Hyper-V completed the restore process automatically rebooted the VMs.

One of the first things we noticed was that that vCPUs were running at a constant 100%. The Task Manager Processes tab showed a series of HP/CPQ services causing the problem.

image

So, we went in and disabled all of the services then shut them down.

Once we rebooted the VMs the HP services were no longer an issue.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Friday, 3 June 2011

Intel Server Board S3420GPRX At Full Capacity – 32GB RAM – A Great Virtualization Platform

After deliberating over which set of 8GB sticks of RAM to purchase to outfit our single socket virtualization platforms with a full 32GB compliment we decided to go with the following part:

  • Kingston Value RAM: KVR1066D3Q8R7S/8Gi

There is also a 1333MHz version of the Intel certified RAM from Kingston but there were some questions around whether that particular model would back itself down to 800MHz which is where a memory channel will go speed wise when two quad ranked sticks of RAM are installed.

image

The screenshot above is via an Intel Remote Management Module.

  • Intel Server Board S3420GPRX with I/O Shield (previous blog post)
  • Intel Xeon Processor X3470 at 2.93GHz
  • 32GB Kingston ECC 1066MHz
  • Intel RS2BL080 RAID + Battery Backup
  • 6x 300GB 15K Seagate SAS (5x RAID 5 + 1x Hot Spare)
  • Intel Server Chassis SC5650DP with hot swap backplane.

The system is fairly quiet and is quite quick. We are expecting this configuration to more than meet our client’s needs.

One thing to note when setting up standalone virtualization boxes with the full GUI OS installed is to change the power settings to High Performance.

image

This particular configuration will be running:

  • Windows Small Business Server 2011 Standard.
    • 2x vCPUs, 16GB RAM
  • Windows Server 2008 R2 Standard in RDS/RemoteApp mode.
    • 2x vCPUs, 4GB RAM
  • Windows Server 2003 R2 Standard (P2V) running legacy LoB.
    • 1x vCPU, 2GB RAM
  • Windows 7 Enterprise x64 (one to four or five desktops).
    • 2x vCPUs, 1.5GB-2GB RAM each.

Our client is a small non-profit with 8-11 seats depending on the time of year. We are quite confident that they will be happy with their new setup once we have migrated them from their current SBS 2003 R2 Premium.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 18 May 2011

Microsoft Download: Best Practices for Virtualizing Exchange Server 2010 with Windows Server 2008 R2 Hyper-V

The following document is available for download on Microsoft’s Download site.

image

The document is an excellent source of great information on all aspects of virtualizing Exchange 2010.

Since SBS 2011 contains Exchange 2010, this document is for us! :)

From the document on sizing the host server:

Hyper-V Root Sizing

The largest consideration for sizing the Hyper-V root server is accommodating the guests it will support. However, there are a number of other factors to take into account:

  • When calculating the RAM requirements on the Hyper-V root server, plan for an additional 1 GB or more of RAM for management of Windows Server 2008 R2.
  • Plan for a dedicated network interface card (NIC) for managing the Hyper‑V root server. This card should not be connected to a local Hyper-V virtual switch.
  • For a simple virtual network configuration that establishes connectivity to an external network, we recommend that you have at least two network adapters on the server running Hyper-V: one network adapter dedicated to the management operating system so you can access it remotely, and one or more network adapters dedicated to the virtual machines.
  • If using live migration, plan for a dedicated NIC of 1 GB or higher due to the large amount of data moved across network.
  • If Internet SCSI (iSCSI) storage is being used, choose dedicated, separate NICs for iSCSI storage.
  • Plan for separate LUNs/arrays for the management operating system, guest operating system virtual hard disks (VHDs), and virtual machine storage.
  • Management operating system and VHD LUNs should employ a redundant array of independent disks (RAID) to provide data protection and improve performance.
  • For blade servers that have two physical disks, use the two physical disks for the host server only. Have the guests on direct-attached storage exposed as pass-through disks, or a separate storage area network (SAN),
  • In a Hyper-V environment, a temporary memory storage file (BIN file) is created and maintained for each guest virtual machine. The size of each BIN file is equal to the amount of memory allocated to the guest virtual machine. The BIN file is stored alongside the Hyper‑V guest virtual hard disk and should be taken into account when determining the amount of disk space required on the Hyper‑V root server.
  • The hypervisor running on the Hyper‑V root server has to manage each of the running Hyper‑V guests, resulting in extra load on the root server processors. This overhead can vary and a conservative allowance of 10 percent overhead should be allowed when sizing the host processors.

The document is definitely worth the read . . . right through.

For those of us that have been configuring hardware and/or building out hardware for server OSs hosted on Hyper-V the document provides a good guideline for us to investigate other avenues of systems design and configuration including Hyper-V Clusters.

It can also help us to tailor our standalone solutions for new SBS 2011 VM based deploys on standalone Hyper-V hosts since Exchange 2010 seems to be the number one question mark when it comes to configuring the host hardware.

Hat Tip: Susan Bradley

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Thursday, 7 October 2010

Intel Server System SR1695GPRX 1U 1P 4x Hot Swap = Excellent SBS Virtualization Platform

The question was asked a while back in the comments section about the platform we would use to virtualize both servers included with SBS 2008 Premium.

It is our preference to set up and install rack mount server products so that everything can be mounted in a relatively inexpensive enclosure thus keeping them physically secured.

Standalone Virtualization Server

To date, we have been using the Intel Server System SR1630HGP outfitted with an Intel Xeon X3450 or X3460 CPU and 16 GB of RAM. The RAM would either be four 4 GB Kingston Intel tested DIMMs or recently we have been looking into the 8 GB Hynix Intel tested DIMMs that we can get branded as a SuperMicro product.

We then install an Intel RS2BL040 RAID controller with the battery backup and three 300 GB or larger Seagate 15K RPM SAS drives.

  • Intel Server System SR1630HGP(NA) 1U 1P rack mount server system
    • 3x hot swap bays for SAS/SATA
    • 2x Intel Gigabit NICs
  • Intel Xeon Processor X3450 or X3460
  • 16 GB ECC RAM (4x 4GB Kingston Intel Approved)
  • Intel RAID Controller RS2BL040 PCI-E 8x Gen 2.
    • Intel RAID Smart Battery Backup
  • 3x 300 GB Seagate 15K.6 or 15K.7 SAS drives
  • Advanced rack mount rail kit for in-rack servicing (AXXHERAIL or AXXHERAIL2)

The newer Intel Server System SR1630HGPRX 1U 1P system is an “almost there” as far as needed product features in an entry level 1U server. We gain access to remote KVM over IP via the RMM3LITE add-in along with the five NICs on the server board. One NIC will be dedicated to the RMM3LITE while the other four are enterprise class Intel PRO/1000 EB NICs that support hardware acceleration for virtualization features.

Since they have become available here in Canada recently we have been using them as our base platform for all 1U 1P server systems.

Ideal Standalone Virtualization Server

As mentioned above, Intel has been moving towards providing us with Intel branded server systems that compete with Tier 1 systems that have had needed server features such as remote management and multiple NICs for years. This is a very welcome change in the rack mount product line.

The system we would configure for a client requiring a standalone server with the Hyper-V role set up on it and SBS 2008 along with Windows Server 2008 as guests would be as follows:

  • Intel Server System SR1695GPRX2AC(NA)
    • Dual power supply version of the server system.
    • 5 Intel Gigabit NICs (4x EB series)
  • Intel Xeon Processor X3460
  • 16 GB Kingston ECC RAM (4x 4 GB Intel Approved)
  • Intel RAID Controller RS2BL040
    • We would option out the RAID battery.
    • Cost wise it does not make sense to use the budget I/O Expansion Module RAID controllers.
  • 4x 146 GB 15K Seagate SAS drives RAID 10
    • Trays support both 3.5” and 2.5” drives so X25-M SSD would be an option to our clients.
  • Intel Remote Management Module 3 (AXXRMM3LITE)
    • Gives us out-of-band remote KDVM console access to the system whether the host OS is functional or not.
  • Intel Tool-less Rail Kit (AXXHERAIL2)
    • Quick and easy access to the chassis.

The Intel ServerConfigurator Site shows the new server system product but there are still some parts like the dual and quad port Gigabit I/O Expansion Modules (product site) that are missing.

image

Those missing components are important in that the SR1695GPRX provides an excellent platform for an inexpensive 2 node Hyper-V Server 2008 R2 cluster using iSCSI for SAN access.

We posted a base server configuration sheet similar to what our clients would get on our Web site:

The premium for this particular base 1U versus our SBS base pedestal is actually not that high. Since we are going to be running both the SBS 2008 OS and the Windows Server 2008 OS on this one box we provide power and cooling savings over the 36 month life of the system.

Hyper-V Features

Now, the one thing that we would miss with the SBS 2008 Premium setup would be the hot swap disk capabilities that we have in the R2 version of Hyper-V. Given that the cost of an Open Value License plus SA is not that expensive year over year we would discuss the option of running Windows Server 2008 R2 Standard x64 as our host OS. Having hot swap capabilities means no down-time when there is a need to swap out external USB/eSATA backup drives.

Once SBS v7 RTMs we will have a Premium SKU that adds a separate Windows 2008 R2 Standard license just as SBS 2008 Premium adds a Windows Server 2008 Standard license. When that happens then we can use the 1+1 licensing of the Windows Server 2008 R2 Standard to virtualize our SBS v7 “Premium” solution.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 6 October 2010

Promise VTrak Performance Graphs Part II

We have brought our client’s Promise VTrak E310sD RAID storage online and are in the process of restructuring the IMS cluster’s storage to incorporate the new addition.

Our SBS 2008 VM is currently moving its WSUS content over to the new VTrak located storage while we are also in the process of moving Windows 7 desktop OS VHDs over to the VTrak as well.

image

image

image

We will continue to monitor the VTrak’s performance when our client’s facility comes online early tomorrow morning.

All user’s redirected data will be located on the VTrak as will a mapped Company folder that will hold all of their data.

The storage that we have freed up on the IMS SAN will be reallocated to their SQL server and to expand the SBS 2008 VM’s OS partition.

MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Tuesday, 5 October 2010

SBS v7 Safe Mode and VM New Cluster Re-Attach Error

We had an SBS v7 server setup that we had initially set up on a Hyper-V cluster here in the shop. While we ended up flattening and rebuilding the cluster we left the logical disk containing the SBS v7 OS VHD alone to reattach to a new cluster.

We just finished booting that SBS v7 VM up and ended up with a strangely stalled OS after logging on. For some strange reason Windows Explorer and thus the desktop would not start.

So, we have booted into SBS v7’s Safe Mode:

image

To check on our network settings:

image

Which sent up the following when we set the correct IP address:

image

Microsoft TCP/IP

The IP address 192.168.40.254 you have entered for this network adapter is already assigned to another adapter (Microsoft Virtual Machine Bus Network Adapter) which is no longer present in the computer. . . Do you want to remove the static IP configuration for the absent adapter?

We clicked the Yes button.

So, as long as the new settings have taken the VM should boot into the OS and hopefully allow us to run the Fix My Network Wizard (FMNW) which will clean up the GUID associated with the previous vNIC.

When the server came up this is what we found in the NIC’s IPv4 properties:

image

Note the missing Gateway setting.

This is what the IPConfig /all looked like:

image

Note the 169.254.142.5 address for the IP instead of the 192.168.40.254 IP address indicated in IPv4 properties. So, we still had no network connectivity happening as we also have a Windows 7 Enterprise x64 VM sitting on the same isolated VLAN.

We ran the Internet Address Wizard to see if we could reseat the IP address configuration. Now, we do not have the appropriate VLAN settings in our Cisco SA520-K9 Security Appliance to allow for communication between the SBS v7 VM and the Internet yet but we will soon. So, we ignored the Router Not Found error and ended up with the correct IP address setup.

We also used our Hardware Independent Restore (previous blog post) methodology to clean up the previous NIC’s GUID.

Once we had completed the above and ran the FMNW we saw the following potential network issues:

image

The results were in:

image

Dive into the logs and we found:

image

So, we verified the settings once again for the vNIC and rebooted the server which came back with:

image

Another 169.254.142.5 IP address. :(

Yet, this is what we saw in the NIC’s IPv4 properties:

image

In the registry editor under the NIC’s GUID we see:

image

The IPAddress setting is blank yet our own SBS v7 IP address is not:

image

So, we set the IP address into the registry manually but the NIC’s IPv4 status still showed a 169 address. We then checked the IPv4 properties for the NIC and it had the wrong subnet setting (255.255.255.255). We reconfigured that one and ended up with the following:

image

Note that now we see both IP addresses!

We restarted the DHCP service to see if it would at least start. It did and we were able to receive an IP address for our Windows 7 Enterprise VM:

image

We rebooted the VM to see if the IPv4 settings would stick.

image

They seemingly did:

image

Somehow, this process did not turn out to be as simple as we had hoped.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Monday, 12 April 2010

In-Person: SBS and Clustering on IMS – Date, Time, Place, and Registration

Into clustering? Into clustering in the SMB space?

Want to know more about the technical aspects of standing up a Hyper-V Server 2008 R2 based cluster?

Then this is the event for you!

The time and place:

  • Event Code: 147718
    04/20/2010
    06:30 PM - 09:00 PM
    Welcome Time: 06:00 PM
    Time Zone: Mountain
  • NAIT Main Campus : HP Center
    10504 Princess Elizabeth Avenue
    Room WB114
    Edmonton, AB T5G 3H1
    Canada

image

The room we will be in is not that large, so if you will be coming out, register early!

Since we are now going to have an Intel Modular Server available to us courtesy of Intel, barring any technological barriers, we will have a live unit to work with via remote back to our shop along with some Camtasia captures of some of the early set up steps.

If registration is full, please e-mail me to let me know that you want in. If there is enough demand, we may be able to work something with the venue or schedule a secondary session elsewhere on another date.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Saturday, 10 April 2010

In-Person: SBS and Clustering On IMS April 20th EMUG – NAIT Campus Edmonton

On April 20th at the NAIT campus starting at 1830Hrs (6:30PM) I will be running through some key points on building a Hyper-V Server 2008 R2 based cluster on top of the Intel Modular Server.

The specific room details, time of the event, and a link for registration will be posted on our Web site as soon as they are known. A calendar item is already in place.  A follow-up post will also be done here via the blog when the specifics are known.

Some clustering topics that may be covered:

  1. Server and cluster install orders.
  2. IMS Storage cluster configuration options.
  3. IMS Network configurations for High Availability.
  4. Node storage configuration for High Availability.
  5. Hyper-V Server 2008 R2 node binding orders.
  6. Hyper-V Management OS based network configuration.
  7. Failover Cluster Management console.
    1. Clustered Shared Volumes and data management.
    2. Live Migrations.
    3. FCM cluster networking.

Depending on timing, we will be able to present a pretty good and specific focus on some aspects of what it takes to get a cluster up and running successfully.

The idea is to work with the actual products demonstrating the how and why of clustering. There may be a few PowerPoint slides here and there, but I intend to keep this session very technical in nature.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Thursday, 8 April 2010

Hyper-V Guest OS Supported vCPUs Grid

No Hyper-V guest OS is created equal.

So, when it comes to utilizing 1, 2, 3, or 4 virtual CPUs (vCPU), we need to be aware of what the guest OS can support natively whether it will support the installation of Integration Services.

As we have already noted, the ShadowProtect Recovery Environment will run very poorly with more than 1 vCPU assigned (previous blog post) to the VM. Once the VM is restored though, that setting can be changed. We also need to be aware of what the restored OS could support for vCPUs.

We get the following grid which will be partially hidden. It can be clicked on to reveal the full screenshot:

image

Here we have the grid for desktop OSs:

image

The final, and quite large, grid has to do with Integration Services and virtual device driver support in each of the OSs:

image

The above is a partial of the grid.

The reason we were looking into this in the first place was because we are standing up an Evaluation copy of SBS 2000 to look into something. We needed to confirm how many vCPUs the OS could handle.

We already knew that SP4 was required to get Integration Services to install though.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Thursday, 14 January 2010

A fresh SBS 2008 Soon To Be Clustered VM Install And The AnswerFile

We just finished installing SBS 2008 into Hyper-V on the 1U management server that is a part of the Hyper-V clustering setup that will be installed at our client site starting tomorrow.

Once we have the cluster Hyper-V Server 2008 R2 nodes configured on the SBS 2008 domain, we will shut SBS 2008 down, export it, and import it to the cluster and make it highly available.

This is what the base OS install looks like after a successful install:

image

The above close to 14GB is before WSUS has had a chance to synchronize and start pulling down any updates too.

The SBS_AnswerFile.vhd is a 128MB VHD file created in Windows 7 (previous blog post) and attached to the secondary IDE controller on the newly created SBS VM setup in Hyper-V.

We mount the SBS 2008 OS ISO using Virtual CloneDrive (freebie – download site) on the Windows 7 machine and create the needed Answer File. From there, we save that Answer File to the SBS_AnswerFile.vhd.

We have tried mounting the VHD containing the Answer File via IDE and SCSI bus and have had no issue with either. The SBS 2008 set up routine sees the Answer File on either bus.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Thursday, 7 January 2010

Intel Modular Server – Hyper-V Cluster NIC Setup

We need at least three NICs to get our cluster up and running. As we understand things, the cluster can be configured on a 2 NIC setup, but this is not optimal.

  1. NIC 1: Internal IP address for management.
  2. NIC 2: Cluster communication.
  3. NIC 3+: Dedicated to VMs.

Here are some screenshots of our configuration.

Gigabit Ethernet Switch Module 1:

image

Note that VLAN designated 99 will be for cluster communication and remain internal only (TBD). We still are not 100% clear on whether we need a physical switch for this part yet.

Ethernet Ports 1 through 10, which are the external ports, are mapped to VLAN 1. The management and VM NICs 2 through 4 are mapped to them.

Gigabit Ethernet Switch 2:

image

All available internal ports for NICs 3 and 4 are mapped to the external ports.

Now, the Hyper-V Server 2008 R2 OS has not necessarily picked up the NIC mapping as we would expect:

image

Note that Node 3 has not had the cluster subnet assigned to it yet as the IP is still 169.254.96.93.

Once we have all of the IPs in place, we will domain join the three Nodes.

From there, we have the Failover Cluster Management (TechNet article on Server 2008 clustering A+) feature installed on the separate 1U that we will use to run the Validate a Configuration Wizard.

Then we will hopefully discover where in our configuration we are lacking the proper configuration structures.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Saturday, 2 January 2010

Intel Modular Server – Storage For the Hyper-V Server 2008 R2 OSs

As part of the ongoing set up process for our Hyper-V cluster that will be running three server OSs and five desktop OSs, we need to set aside a bit of storage space for the actual Compute Module Hyper-V Server 2008 R2 OS:

image

So, what we have done here is created a Storage Group called HyperV_OS based on drives 1 and 2 which are both Seagate Savvio 146GB 15K.2 SAS 6.0Gb/s drives.

All of the drives populating the 13 drive bays are the same Seagate model.

Click on either one of the drives in slot 1 or 2 and we get the following:

image

The information breakdown is quite comprehensive as we drill down into the various menus in the Modular Server Control console.

The plan for the balance of the drives is to have slots 3 through 6 set up as a dedicated RAID 10 array for Small Business Server 2008 and the balance of the drives in slots 8 through 13 set up as a RAID 10 for the other two servers and the five desktop OSs.

An Intel SR1630HGP 1U Intel Xeon Processor 3400 Series server with Windows Server 2008 R2 Standard x64 will be a Read-Only DC providing authentication fall back if there is a full shutdown of all systems. The Hyper-V Role is also installed on this box.

Microsoft’s System Center Virtual Machine Manager will be installed on the 1U to facilitate managing the VMs.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 16 December 2009

SBS 2008 Backup Recovery To Hyper-V OEM Services Caveat

One of the services we offer to our clients is the rotation of their backup drives along with a quarterly test restore of the full server to Hyper-V or one of our lab servers.

When restoring to Hyper-V, one of the things to watch out for on that first boot post recovery are runaway processes. In most cases those processes will be the server manufacturer’s management software searching for the server hardware.

image

The above screenshot is the Services.msc console showing the HP services that we needed to set to Manual before rebooting the now recovered SBS 2008 VM.

When the server comes back up after the reboot, the services running on the server will behave as expected . . . hopefully! :)

Depending on the complexity of the SBS 2008 setup, a full restore to production levels should not take more than 4 hours with 2 virtual CPUs, 6GB RAM, and the appropriate storage volume(s) applied.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 15 October 2008

SBS 2008 - Physical and Virtual Product Keys

For those of us on TechNet, MSDN, or soon to be Open Licensing, we will see that there are two sets of product keys we are given to activate the server:
  1. Physical: This product key will be bound to the physical hardware the server OS resides on.
  2. Virtual: This product key will activate the OS, but not require reactivation if memory, CPU cores, or any other virtual hardware configuration is changed.
Microsoft KB949748: Description of the changes that were made to the product activation process for Windows Server 2008 in a virtual operating system environment.

The virtual product keys apply to server OSs only and will be provided with Fully Packaged Product and OEM product. In the case of OEM product, there are some restrictions on preinstallation.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists

*All Mac on SBS posts are posted on our in-house iMac via the Safari Web browser.

Tuesday, 4 September 2007

SBS - Some Relevant Microsoft Virtual Labs

New to SBS or looking to brush up on those skills? Need a free way to get some experience?

Then, check out these virtual labs. They don't tie up one of your systems, and they are always on.

MS Events posted March 30, 2007:

Event ID: 1032336513: TechNet Virtual Lab: Deploying Microsoft Windows Small Business Server 2003 R2 Installing and Configuring the Server Computer (Part 1 of 2).

Event ID: 1032336514: TechNet Virtual Lab: Deploying Microsoft Windows Small Business Server 2003 R2 Client Features and Windows Server Update Services (WSUS) Integration (Part 2 of 2).

MS Events posted October 24, 2005:

Event ID: 1032286878: Microsoft Small Business Server 2003 Technical Overview Part 1 Virtual Lab.

Event ID: 1032286879: Microsoft Small Business Server 2003 Technical Overview Part 2 Virtual Lab.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists

*All Mac on SBS posts are posted on our in-house iMac via the Safari Web browser.

Saturday, 18 August 2007

Virtual Server - VM Memory & CPU requirements

We have been working with Virtual Server 2005 R2 SP 1 for our virtualization needs.

The two key physical limitations to the number of virtual machines, in our experience, are the amount of memory installed and the speed and number of cores on the CPUs.

Windows Server 2003 Standard R2 x64 serves most of our virtualization needs. With the /PAE switch in boot.ini, we get to address as much RAM as we need.

For Intel based uniprocessor servers we are limited to 8 GB of RAM. For dual processor servers we are limited to 32 GB of RAM.

We tend to configure one (1) virtual machine for each core on a processor. For a Quad Core uniprocessor server we would run a maximum of 4 virtual machines. For a V8 server, dual Quad Core CPUs, we would run a maximum of 8 virtual machines.

This setup is, of course, based on the limitations of VS 2K5 of one core to one virtual machine.

VMWare Server would give us the option of dual SMP - two cores - for a virtual machine if the situation warranted. We would reduce the number of VMs running on the host OS accordingly.

A good portion of our client based virtualization needs are for remote desktop serving. The ability to run virtual XP Pro or Vista Business desktops provides flexibility for Group Policy based desktop security, user and application limitations via Group Policy, Line of Business apps that may not be able to be installed on a Terminal Server, Remote Web Workplace access via "Connect to my computer at work", and more.

An XP Pro VM can run quite comfortably on 512 MB of RAM while on a dual 3.06 GHz Intel Xeon based server. Virtualization is one place where Hyper-Threading actually works.

Windows Vista Business will require a minimum of 1 GB of RAM when running virtually. Anything less than that and Vista takes a pretty heavy performance hit.

We tend to set at least 2 GB of RAM to a virtualized SBS installation. That is the minimum we would install on a physical SBS installation, so we stick with it for VMs.

Windows Server 2003 Standard R2 serving DNS to the Internet can run on 256 MB of RAM. Install Exchange and the memory requirements jump up to at least 1 GB with 2 GB being better. ISA virtualized will run okay on 512 MB but better on 1 GB.

A rule of thumb is to leave a minimum of 384 MB of RAM for the host OS. Make sure that only the host OS basics are installed. For Windows Server 2003 Standard R2, remove or disable all nonessential services to lean out the OS.

So far, virtualization has done great things for our clients and for us. It can greatly reduce the costs of running a few extra dedicated remote desktops when all of the client's staff is laptop based. It can provide a single box solution for a number of light duty server roles that are easy to backup and restore as needed and in short order.

For those of us in IT, it eliminates the hardware/$$$ limitation on our testing labs. One V8 server will serve most small shop's server/client VM environmental needs. No more need to have four, five, or more boxes with a KVM or two just for those lab situations where we need to test whether our client boxes will blow up with the next run of updates and patches!

It also gives us a tremendous time saver: Undo Disks! With undo disks enabled, if that run of patches or updates does blow up the virtualized client SBS or other server box, we can undo the patches by discarding the changes and then start again. Hopefully we will be able to figure out which patch is causing the problems with what installed component and go from there.

All in all, virtualization can provide an excellent way for us to create some pretty neat solutions for our clients with a very attractive price point.

This is needed to enable Windows Server 2003 Standard R2 x64 to access installed RAM above 4 GB: Microsoft KB 283037: Large memory support is available in Windows Server 2003 and in Windows 2000

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists

*All Mac on SBS posts are posted on our in-house iMac via the Safari Web browser.

Monday, 19 March 2007

Need to familiarize yourself with SBS? Try This --->

Do you have a spare machine around with enough memory and processor speed to install a base OS and Virtual Server on top? If you do, the following assumes a little bit of experience with Virtual Server 2K5 R2 as that is what we run our virtual environments on.

You could run your SBS install stages; install some XP desktops, Vista desktops, and another server or servers if you like within the virtual environment.

You could run the entire project virtually, start to finish, without impacting your production environment. If need be, all operating systems can be Eval versions so as to not impact licensing issues.

Running things virtually requires nothing special in the way of hardware or software.

To get to RWW on the virtual SBS domain via your internal network do the following:

Virtual SBS: Create an internal network accessible only by the workstations and SBS NIC 1. Add a second NIC to the virtual SBS box that is attached to the machine's physical NIC so it can pull an IP from your internal DHCP server.

On your internal DHCP server, create a reservation for the MAC address of the virtual SBS NIC 2.

On your internal DNS server, add an (A) record to the IP address reserved for the virtual SBS server above: virtualsbs.mydomain.local (your domain setup) = IP 192.168.xxx.xxx (your IP subnet)

Run the SBS setup on your virtual server, complete stage 1, post stage 1 install and configure the base installation as you normally would and then continue on with stage 2 for the complete SBS install.

Internet Wizard URL: same as your internal DNS (A) record: virtualsbs.mydomain.local

You will be able to send e-mail from the virtual domain, only SMTP e-mail coming in will not happen if you already have an SBS server, or Exchange server on your internal network. POP3 Connector solution could be implemented here if you want full e-mail functionality on the virtual domain. RWW will be accessible via your Web browser internally: http://virtualsbs.mydomain.local/remote.

Install the workstation OSs. This can be done at the same time as the SBS stage 2 install.

Once you have the SBS install, Premium Tech (if needed), and the ToDo list finished, you can go ahead and create some virtual users and computers and then run through the Add Computer wizard for the XP and/or Vista workstations. This gives you the opportunity to install the SBS/Vista RipCurl! ;)

The above will give you a complete install, start to finish. Mess up? No worries, start again. You will be able to run Eval versions for about 6 months give or take from the install date. This is more than enough time to play with the virtual SBS environment to get comfortable with the look and feel of installing SBS.

You can get SBS 2K3 Premium SP1 Eval on eBay without a problem, and SBS 2K3 Premium R2 Eval by purchasing the R2 Eval pack which is little more than shipping and handling from Microsoft. XP Pro can be had via eBay, as can Office, and others. Vista trial can be had via any Vista RTM media obtained via TechNet, MSDN, or a DVD that came with a system.

This setup also gives you the opportunity to explore Group Policy settings without creating havoc on a production SBS environment. Create and destroy OU's and policies. Learn how to get very granular with the application of your policy settings. No risk of GP tattoos on your virtual desktops ... you can pause the virtual desktops to be hit with the GP before hand and copy the VHD. Save it for later when you want to reverse things. The same is true for the virtual SBS VHD.

Need to figure out how to install software to certain machines via GP? Then this is the place to do it! Office 2003, 2007, Windows Defender for XP, and more can be distributed via GP (Eval and OLP versions for Office).

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists