Wednesday, 8 December 2010

SBS 2003 – MSExchangeIS Error 9646 – Exceeded Maximum Objects

One of our SBS 2003 sites had the following in their morning report:

image

In the Event Logs we found:

image

Event Type:    Error
Event Source:    MSExchangeIS
Event Category:    General
Event ID:    9646
Date:        12/8/2010
Time:        9:46:25 AM
User:        N/A
Computer:   SBS
Description:
Mapi session "/o=DOMAIN/ou=first administrative group/cn=Recipients/cn=FirstLast" exceeded the maximum of 32 objects of type "session".

For more information, click http://www.microsoft.com/contentredirect.asp.

A quick search turned up:

The instructions were as follows:

  1. Click Start, click Run, type regedit in the Open box, and then click OK.
  2. Locate and then click the following registry subkey:

    HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\MSExchangeIS\ParametersSystem

  3. If the Maximum Allowed Sessions Per User entry does not exist, do the following:
    1. On the Edit menu, point to New, and then click DWORD Value.
    2. Type Maximum Allowed Sessions Per User as the entry name, and then press ENTER.
  4. Right-click the Maximum Allowed Sessions Per User entry, and then click Modify.
  5. Click Decimal, type the value that you want to set in the Value data box, and then click OK.
  6. Exit Registry Editor.
  7. Click Start, click Run, type services.msc in the Open box, and then click OK.
  8. Click the MSExchange Information Store service, and then click Restart Service.

We configured the registry setting at 96. The default is 32.

Once we restarted the Information Store the user could connect to Exchange in their Outlook 2007.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

CaseWare Working Papers – Disabling SMB2

We have a small 5 seat accounting firm that is having nothing but grief with their CaseWare Working Papers 2010 accounting application.

We had them update their systems to CaseWare’s R7 update but that did nothing to improve the product’s stability.

So, we disabled SMB2 on their relatively new SBS 2008 setup.

image

We had a bit of a nervous time after making the change and rebooting the server. It took almost 10 minutes for us to see the logon request!

This particular server has an Intel Remote Management Module 3 installed so we were able to make the change and watch the entire reboot session as though we were sitting right in front of the server.

Now that the change has been made we will be monitoring their network performance especially when they are working on their own client’s larger QuickBooks files we believe that QB performance will be a pain point once SMB2 is disabled.

We are working on a NAS based solution for our larger clients if we cannot get any kind of stability out of Working Papers 2010 as disabling SMB2 would take too high a cost in network performance.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Tuesday, 7 December 2010

URL Shortening – Check That Link Out Before Visiting – LongURL.org

The link comes courtesy of Matthiew Suiche.

The LongURL.org service allows us to plug in one of those ultra-short URLs and view the Web site on the other end of it.

This service gives us a quick and easy way to find out whether there is a problem on the other end of that link.

image

Check it out. In the age of Twitter and the like we can make good use of it.

UPDATE: An additional link for Matthieu: MoonSols.com

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Intel Modular Server – Talking Component Redundancy with a Client

This is a quote of one of our posts that can be found here:

How do we explain the value of redundancy in system components and even in clusters? . . . It has to do with the discussions with the business owner and/or contact.

We do a cost evaluation relative to the total revenue of the client's company. That is, we ask for a general figure for the total revenue for the year. What we have discovered is that most company's users are valued at about $100/Hour based on 1,900 hours worked per year. The figure varies above and below depending on the type of business, industry, and how profitable they are.

So, when we are talking with a business owner of a 15 seat accounting firm, that is the number we would probably come up with after receiving a general gross revenue figure. That means that one hour of down time costs the firm roughly $1,500/Hour. This is about where building a cluster for a client becomes a reasonable option.

In the case of the IMS and the extra components for redundancy we would break things down as follows based on a 36 month lifecycle (probably longer):

  • Ethernet Switch Module $1,900
    • ESM cost per user: $0.02/Hour
      • 1900/3 years = $633/Year
      • 633/15 users = $42.20/User
      • 42.20/1900 = $0.02/Hour
  • Storage Controller Module $2,600
    • SCM cost per user: $0.03/Hour
  • All three paper pack keys (SharedLUN, Storage, Admin) $1,900
    • Admin packs cost per user: $0.02/Hour

Since our primary server setup on the IMS are Hyper-V clusters, why would we be delivering a solution that has any single points of failure? That kinda defeats the purpose of building a cluster in the first place.

Say an SCM fails and the IMS only has one installed. It takes us an hour to get there with a spare that _we_ would have to pay for, install the replacement, and bring things back up (hopefully).

Total cost to the client:

  • 2 hours of downtime $3,000
  • 1 hour of user catch-up time $1,500
  • 2.5Hours of Emergency Rush Service $750
  • Total Cost: $5,250.00

The above situation more than pays for both the extra SCM and the ESM too.

Once we break down the costs over the life of the system per user the cost of the components comes into perspective. Most folks would sticker shock on a two or three node cluster anyway if there was not a discussion like the above to prepare them to see the _actual_ cost of the system per user for the life of the solution.

Now, that is just the _cost_ associated with the extra components.

Where the value comes in is in developing the business owner’s and/or contact’s understanding of how their user’s efficiency will increase significantly with training and over time with usage. This discussion is also based on the above figures and ends up showing a repay on the total cost of the system as being 8-12 months.

That leaves 24 months of _making money_ over the lifecycle of the solution for the client.

Speaking to business owners _as a business owner_ and not a tech geek makes the sale almost every time. Almost all small business owners understand how something can improve their business and thus generate more money for them. That’s where those acronyms come in like TCO and ROI . . . but without all the fancy lingo. Just numbers, business efficiency, new abilities, and value for those abilities.

Oh, and clustering and redundancy equals _insurance_.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Friday, 3 December 2010

Adobe Acrobat Error – Crash On Two Opened Documents ATIUMDAG.DLL

A client of ours has been experiencing a crash in Adobe Acrobat when they try and open more than one PDF file.

The component responsible for the crash was ATIUMDAG.DLL.

When this crash happens uncheck Use 2D graphics acceleration under Page Display in Acrobat’s Preferences.

image

Close Acrobat after making the settings change and then try opening two different PDF documents. Acrobat should open properly from there on.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

US QuickBooks 2011 R1 – Third Party Components Install Error Plus Error on MSVCR90.DLL And More - Unresolved

We have a client that we set QuickBooks 2011 R1 (Accountant’s Edition) up for a while back. Then, the user went to use the software and it kept crashing.

The QB 2011 software was installed via RDP session by us.

The strange thing was that when we connected to the user’s desktop via Remote Assistance (SBS 2008 backend) QB 2011 would open with no issues. If the user connected to their desktop via RDP QB 2011 would open without a problem. Note that this user is operating as a Standard User.

We elevated the user to Local Admin status with no change. QB 2011 would not run unless a Remote Assistance session was active or they were connected via RDP.

We left the user at Local Admin status and had them uninstall QB 2011. Once they did so we had them attempt to reinstall only to get hit by:

image

Intuit QuickBooks Installer

Third party components could not be located.
The installation cannot proceed and will now exit.

Okay, so what does this mean?

We need to go get the R2 version of the product as the error is being generated by the RTM or R1 product which was delivered via DVD.

Once we downloaded the R2 product via the above support page the user was able to install, but it still kept crashing outside of an RDP or Remote Assistance session:

image

Event 1000, Application Error

Faulting application QBW32.exe, . . . faulting module MSVCR90.dll.

So, while connected we had the user run the internal update feature and voila, we have updates:

image

Sure enough, after downloading and re-opening QB the R2 was now R3P:

image

After all of this we disconnected our Remote Assistance session and had the user log off and log back on again to see if they could start QB on their own. QuickBooks crashed again.

We then tried the Reboot.Bat script to register QuickBooks components as per:

image

The script did not solve our problem. We still had the same application crash on the same DLL.

A search on the DLL brought up the following KB:

This is the version set of the DLL on the problematic workstation:

image

MSVCR90.DLL Properties

Product version: 9.00.21022.8
Product version: 9.0.30729.1

Note that in the end the above hotfix was specific to Visual Studio 2008 so we were essentially barking up the wrong tree. This KB confirms it too:

With a further amount of searching we found this Intuit Support article:

image

Note the specific reference to the MSVCR80.DLL. While not the same one as the DLL we are dealing with, it is close enough. We are at step 6 where we need to perform a clean uninstall of QuickBooks 2011.

If that works, we will update this post as well as publish a new post with a pointer back to this one. If it does not, then we are against the wall as Intuit has not given us any indication that they know what is going on either.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Outlook 2010 – “My Address Book Is Gone” Importing The NK2 File

How many of us have heard, “My address book has disappeared!” after migrating the user to a new workstation.

We learned the hard way in the past to migrate the NK2 file, or what is called the Nickname Cache, to the new workstation _after_ creating a new one in Outlook 2007 or earlier.

With Outlook 2010, we need to go through an import process in order to get those nicknames into the user’s new Outlook mailbox setup.

To import .nk2 files into Outlook 2010, follow these steps:

  1. Make sure that the .nk2 file is in the following folder:

    %appdata%\Microsoft\Outlook

    Note The .nk2 file must have the same name as your current Outlook 2010 profile. By default, the profile name is "Outlook." To check the profile name, follow these steps:

    1. Click Start, and then click Control Panel.
    2. Double-click Mail.
    3. In the Mail Setup dialog box, click Show Profiles.
    4. image
    5. The original Outlook 2007 file is shown above.
  2. Click Start, and then click Run.
  3. In the Open box, type outlook.exe /importnk2, and then click OK. This should import the .nk2 file into the Outlook 2010 profile.
  4. image 
  5. Note After you import the .nk2 file, the contents of the file are merged into the existing nickname cache that is currently stored in your mailbox.
Note The .nk2 file is renamed with a .old file name extension on the first start of Outlook 2010. Therefore, if you try to re-import the .nk2 file, remove the .old file name extension.

Make sure to follow the profile name verification as the import does not work if that step is not followed. The Outlook 2007 file was named Default.NK2.

Also:

image

Our Outlook.NK2 file did not get the .OLD extension tied onto it after the file was imported into Outlook. We could tell that the file was indeed in there because typing a letter in the TO field of a new e-mail brought up _lots_ of e-mail addresses.

Obviously our client would not have been too happy if their address book was deleted.

Now, what happens when we want to move them from this system to another system whether with Outlook 2010 or newer version of Office has yet to be seen. Given that the above KB is a “Fast Publish” article, we can only hope that an avenue to move that nickname cache between Outlook 2010 profiles or to newer Office versions will happen.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Thursday, 2 December 2010

CaseWare Working Papers 2010 – Network File Locations Errors

Just lately we have been seeing a lot of problems with CaseWare Working Papers 2010 and the files associated with the program being located on Windows Server 2008 and Windows Server 2008 R2 (including SBS) file shares.

CaseWare has this to say:

image

CaseWare International highly recommends disabling SMB2.

Specifically, the problems have reared their head with the Working Papers R2 and R3 updates applied.

This situation really gives us cause for pause.

Why, you might ask?

Because CaseWare’s recommendation to disable SMB2 (the network sharing protocol that gives us 100MB+/Second file copies on the network) takes us a huge step backwards in network performance.

Now, for a small accounting firm this may not be a big deal . . . depending on how many QuickBooks and Simply clients they are bookkeeping for. Or, how many large files are moving around on the network.

As soon as we disable SMB2 we are at a disadvantage for any large data sets moving around on the network. So, for our larger accounting firm clients with quite a number of QuickBooks files open simultaneously plus their regular network traffic we may start to hear complaints about poor network performance.

In our opinion, the suggestion to disable SMB2 comes at too high a cost for most accounting firms.

With the just released R7 for CaseWare Working Papers 2010 we are hoping that we will see things settle down to the same level RTM had (virtually no issues).

If not, we may be looking at setting up a small NAS appliance with a folder share _just for CaseWare files_ so as to not impact the overall performance of the network.

BTW, our last attempt to contact CaseWare support took 5 days before their initial response which was to e-mail another department and then _another_ 3 days before the answer finally came through. Eight days to straighten out an activation issue with CaseWare Working Papers 2010 . . . ouch.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

ShadowProtect 4.0.1–Windows 7 Ultimate x64 Restore Good To Go

We supplied a number of new machines into a new client when we did a new SBS 2008 install not too long ago.

One of the machine’s hard disks was causing some flaky behaviour and throwing Disk errors in the Event Logs.

We installed ShadowProtect 4.0.1 Desktop edition on the machine yesterday and set up a scheduled backup to run every hour to a network share.

When we arrived this morning we ran a final Incremental backup prior to shutting down the system. We swapped out the bad drive for a new one and then booted off of our ShadowProtect IT Edition’s USB flash drive.

Once we created the necessary disk signature, rebooted, we were able to restore the 100MB partition that Windows 7 creates and then the actual system partition.

There was some initial concern because that 100MB partition normally does not have a drive letter associated with it plus the restore process flagged a bad BCD Database restore in red.

Once we ran through the actual system drive’s restore process there was a note in the Details pane that showed that the BCD Database was edited and successfully corrected.

We then closed ShadowProtect IT Edition and the system rebooted. It complained about not being shut down properly, but Windows 7 Ultimate did indeed boot up without a hiccup.

A quick check in Disk Manager showed that 100MB partition as not having a drive letter and everything was good to go!

Total time to swap out a bad drive and restore the system on an Intel Core 2 Duo E8500 on an Intel DQ45EK Mini-ITX motherboard with a 320GB 7200 RPM Momentus was about an hour and 10 minutes. A full OS install, driver install, updates, and application install would have been about 3-4 hours.

Note that ShadowProtect must be installed and configured on a Backup Schedule in order to have access to creating Incremental backups. A manual backup (Backup Once) will not allow for any incremental backups.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Monday, 29 November 2010

Intel’s New Server System SR1695GPRX 1U 1P 4 Hot Swap Drive

We just received a new Intel Server System SR1695GPRX 1U uni-processor system that has four hot swap SAS/SATA drive bays capable of handling both 3.5” and 2.5” drive sizes out of the box.

image

This new Intel Server platform is an excellent fit for the SMB space in that it offers the same enterprise class 1U server features as a dual processor unit but at a single processor price level.

This configuration has been on our wish list for _a long time_ now.

  • 1U profile provides for lots of room in that 24U enclosure.
  • Single processor leads to a lower cost point based.
    • A single processor server board with extended RAM capabilities.
  • 4 hot swap drive bays give us access to RAID 10 configurations.
  • A full height PCI-E slot for a high performance RAID controller.
  • Intel Remote Management Module 3 (LITE) capable.
    • Takes over NIC5 to provide out-of-band console access via Web.

image

As we can see the server system also has dual redundant power supplies which is absolutely critical to providing our clients with needed hardware redundancy. On the right hand side at the bottom of the above shot are two ports where we can plug in a couple of additional I/O modules such as dual Intel Gigabit server NICs to bring the total NICs available on this box to eight (without the RMM3LITE NIC).

  • The SR1695GPRX is dual power supply capable (watch that part number!)
  • Can add another set of dual port Intel Gigabit server NICs.
  • Can add an entry level performance SAS RAID I/O module without using the PCI-E slot.
    • Some RAID I/O modules have the ability to add a cache battery.

Given that we can have up to eight NICs in this system we now have an excellent platform for a single server Hyper-V host when deploying SBS 2008 plus the second server or as an inexpensive node in a Hyper-V cluster attached to iSCSI storage for Clustered Shared Volumes.

image

The shot above is just prior to dropping the airflow baffle back on between the fans and the CPU and the memory.

The RAID controller is an Intel RS2BL080 with battery backup situated near the top of the shot (shiny object). We have an RS2BL040 on order but it will not be here until the end of the week. Since Intel RAID controllers can be inter-changed we have this Hyper-V server built up already and will swap in the production controller when it shows up.

From now on this particular hardware configuration will be our principle offering for any situations where we need a 1U server system whether the client is looking for standalone server systems, a couple of virtualized server operating systems, or even a small two node cluster based on two of these units and one or two NAS devices that act as iSCSI targets.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Friday, 26 November 2010

Toshiba Tecra S11 Core i7-620M 160GB X25-M WinSAT Score

We have just completed configuring a number of new Toshiba Tecra S11 laptops with 160GB X25-M Intel SSDs.

Our own Tecra S10 WinSAT scores can be found here:

The Tecra S10’s scores were:

  • Disk  Sequential 64.0 Read              203.74 MB/s        7.3
  • Disk  Random 16.0 Read                    39.33 MB/s        6.3
  • Disk  Sequential 64.0 Write              88.15 MB/s          6.3
  • Total Run Time 00:01:25.32

The Tecra S11’s scores were as follows:

  • Disk  Sequential 64.0 Read                   240.75 MB/s          7.5
  • Disk  Random 16.0 Read                       215.20 MB/s          7.8
  • Disk  Sequential 64.0 Write                  103.40 MB/s          6.6
  • Total Run Time 00:01:10.07

The second stat in the S10’s numbers must have been an anomaly. We will revisit the WinSAT test on that unit to see how the performance has stood up over time.

There is a tangible performance difference on the Core i7-620M based Tecra S11 versus the Core 2 Duo T9600. The system is a lot more responsive in so many ways.

So, it is not surprising to see that the SSD performance on the new S11 takes a step up versus the previous generation.

In the end, the cost of the SSD is more than made up by our client’s users increased productivity.

While one of the drivers for having the SSD installed has been Windows XP Mode on Windows 7, most of our client’s line of business applications have come up to date and are Windows 7 compatible. There are still a few hold outs, but for the most part XP Mode is slowly being deprecated.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Windows 7 Enterprise Upgrade Edition

Okay, so we cannot plug in a Windows 7 Enterprise OS based flash drive and do an in-place upgrade of Windows 7 Professional.

This is important to note when it comes to any time quoting for things like replacing spindle based hard disks with Intel X25-M SSDs and expecting to drop the OEM default recovery on the SSD and then upgrade to Windows 7 Enterprise using the client’s Software Assurance.

Windows 7 Enterprise will always have a fresh install requirement if the base OS was Windows 7 Professional.

The Windows 7 Enterprise Upgrade version will upgrade certain prior Windows Vista versions though.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 24 November 2010

Laptop Start-up – Stalled At “Please Wait …”

We have been seeing a few situations where a laptop that is not connected to any wired or wireless network connection will hang at “Please wait” for quite a long time.

It took a long time to figure out the right search terms to bring up the above Forums post.

image

While the general consensus among folks on the forum post is to disable the NLA Service, this will kill any connection that the laptop may have to a Home Group, disable the laptop’s ability to change default printers based on location, and more.

So, we suggest trying to set the NLA Service to Automatic (Delayed Start). If that still causes the stall at start up, then change the service to Manual so that the OS can still fire up the service if it is required.

Once the setting change is complete, the laptop should boot up and display the logon screen in essentially the same amount of time whether connected to a network or not.

Hat Tip: Kevin Atkey

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Tuesday, 23 November 2010

Seagate’s New Model Numbering Scheme

We just received a Seagate Partner e-mail that indicates that Seagate is changing the product model numbering scheme.

image

As we can see, the model numbers have changed significantly relative to the current model number structures. In the current scheme The prefix ST3 means 3.5” drive, ST9 means 2.5” drive while the suffix AS is SATA, ES is Enterprise SATA, and SS is SAS. The numbers in between the prefix and suffix would be the size of the drive and then three numbers indicating model specifics.

A breakdown of the model number and what each means is this:

image

What we will end up with will actually be a simpler way to order Seagate drives. No more needing to know the various model numbers for whatever feature we want with a 500GB drive for example. With the new model number scheme the number will remain the same for the 320GB drive across all of is various feature sets while the model number will be specific to those feature sets.

It means that internally we can track all of the various feature sets for inventory purposes but our externally facing collateral will use the one model number to describe a 320GB drive. This makes for a much simpler presentation too.

image

Ultimately, when it comes to ordering product the new model numbering scheme will not make too much of a difference when searching our distribution channels for product. Now, we can search ST31000*SS to find any 1TB SAS drives, ST3500*NS to find any Enterprise SATA drives, and so on. After modifying our wildcard location to ST500* we will find any and all 500GB SKUs available to us. We can then use the same methodology as above to limit our search results to ST500MX* for Mission Critical 500GB drive models or ST*MX to bring up all Mission Critical products.

Note that not all distribution search engines support wildcard searches beyond dropping the asterisk at the end of some alpha characters.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 17 November 2010

Microsoft Bluetooth Mobile Keyboard 6000

One of our Microsoft Wireless Entertainment Keyboard 6000s had its space bar button die. We tried to get things working, but it seems that it would not cooperate.

So, we needed a replacement.

For those of us with bad wrists, in my case due to slinging a wrench for so many years without initial training on protecting them, a wave style keyboard helps to reduce the need to wrist pivot the hands while typing.

We have found that the Microsoft wave style is one of the ergonomic keyboards available.

image 

With this particular keyboard being Bluetooth enabled we were able to pair both the keyboard and the number pad with the workstation’s built-in Intel DP55KG Bluetooth in a matter of seconds.

Key action on the new 6000 provides great feedback with a smooth action. For comparison, it has the feel of a high quality laptop keyboard.

Due to its compact size though, there were some compromises on the number and type of keys included on the keyboard. The one button that we really miss is the right mouse click key. In its place is a blue Fn key for the page up, down, home, end, and other such keys.

image

When working in Word or Outlook it is much easier to tap on that key to gain access to the right click menu for copy and paste or to work with e-mail.

While a user’s preference for a keyboard style is particular to them, there is an added benefit to having the separate number pad for folks that work in accounting offices. So, we will be suggesting this keyboard and number pad combination to our accounting clients.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer