Intel Server System SR1695GPRX 1U 1P 4x Hot Swap = Excellent SBS Virtualization Platform

The question was asked a while back in the comments section about the platform we would use to virtualize both servers included with SBS 2008 Premium.

It is our preference to set up and install rack mount server products so that everything can be mounted in a relatively inexpensive enclosure thus keeping them physically secured.

Standalone Virtualization Server

To date, we have been using the Intel Server System SR1630HGP outfitted with an Intel Xeon X3450 or X3460 CPU and 16 GB of RAM. The RAM would either be four 4 GB Kingston Intel tested DIMMs or recently we have been looking into the 8 GB Hynix Intel tested DIMMs that we can get branded as a SuperMicro product.

We then install an Intel RS2BL040 RAID controller with the battery backup and three 300 GB or larger Seagate 15K RPM SAS drives.

  • Intel Server System SR1630HGP(NA) 1U 1P rack mount server system
    • 3x hot swap bays for SAS/SATA
    • 2x Intel Gigabit NICs
  • Intel Xeon Processor X3450 or X3460
  • 16 GB ECC RAM (4x 4GB Kingston Intel Approved)
  • Intel RAID Controller RS2BL040 PCI-E 8x Gen 2.
    • Intel RAID Smart Battery Backup
  • 3x 300 GB Seagate 15K.6 or 15K.7 SAS drives
  • Advanced rack mount rail kit for in-rack servicing (AXXHERAIL or AXXHERAIL2)

The newer Intel Server System SR1630HGPRX 1U 1P system is an “almost there” as far as needed product features in an entry level 1U server. We gain access to remote KVM over IP via the RMM3LITE add-in along with the five NICs on the server board. One NIC will be dedicated to the RMM3LITE while the other four are enterprise class Intel PRO/1000 EB NICs that support hardware acceleration for virtualization features.

Since they have become available here in Canada recently we have been using them as our base platform for all 1U 1P server systems.

Ideal Standalone Virtualization Server

As mentioned above, Intel has been moving towards providing us with Intel branded server systems that compete with Tier 1 systems that have had needed server features such as remote management and multiple NICs for years. This is a very welcome change in the rack mount product line.

The system we would configure for a client requiring a standalone server with the Hyper-V role set up on it and SBS 2008 along with Windows Server 2008 as guests would be as follows:

  • Intel Server System SR1695GPRX2AC(NA)
    • Dual power supply version of the server system.
    • 5 Intel Gigabit NICs (4x EB series)
  • Intel Xeon Processor X3460
  • 16 GB Kingston ECC RAM (4x 4 GB Intel Approved)
  • Intel RAID Controller RS2BL040
    • We would option out the RAID battery.
    • Cost wise it does not make sense to use the budget I/O Expansion Module RAID controllers.
  • 4x 146 GB 15K Seagate SAS drives RAID 10
    • Trays support both 3.5” and 2.5” drives so X25-M SSD would be an option to our clients.
  • Intel Remote Management Module 3 (AXXRMM3LITE)
    • Gives us out-of-band remote KDVM console access to the system whether the host OS is functional or not.
  • Intel Tool-less Rail Kit (AXXHERAIL2)
    • Quick and easy access to the chassis.

The Intel ServerConfigurator Site shows the new server system product but there are still some parts like the dual and quad port Gigabit I/O Expansion Modules (product site) that are missing.

image

Those missing components are important in that the SR1695GPRX provides an excellent platform for an inexpensive 2 node Hyper-V Server 2008 R2 cluster using iSCSI for SAN access.

We posted a base server configuration sheet similar to what our clients would get on our Web site:

The premium for this particular base 1U versus our SBS base pedestal is actually not that high. Since we are going to be running both the SBS 2008 OS and the Windows Server 2008 OS on this one box we provide power and cooling savings over the 36 month life of the system.

Hyper-V Features

Now, the one thing that we would miss with the SBS 2008 Premium setup would be the hot swap disk capabilities that we have in the R2 version of Hyper-V. Given that the cost of an Open Value License plus SA is not that expensive year over year we would discuss the option of running Windows Server 2008 R2 Standard x64 as our host OS. Having hot swap capabilities means no down-time when there is a need to swap out external USB/eSATA backup drives.

Once SBS v7 RTMs we will have a Premium SKU that adds a separate Windows 2008 R2 Standard license just as SBS 2008 Premium adds a Windows Server 2008 Standard license. When that happens then we can use the 1+1 licensing of the Windows Server 2008 R2 Standard to virtualize our SBS v7 “Premium” solution.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 6 October 2010

Promise VTrak Performance Graphs Part II

We have brought our client’s Promise VTrak E310sD RAID storage online and are in the process of restructuring the IMS cluster’s storage to incorporate the new addition.

Our SBS 2008 VM is currently moving its WSUS content over to the new VTrak located storage while we are also in the process of moving Windows 7 desktop OS VHDs over to the VTrak as well.

image

image

image

We will continue to monitor the VTrak’s performance when our client’s facility comes online early tomorrow morning.

All user’s redirected data will be located on the VTrak as will a mapped Company folder that will hold all of their data.

The storage that we have freed up on the IMS SAN will be reallocated to their SQL server and to expand the SBS 2008 VM’s OS partition.

MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Tuesday, 5 October 2010

SBS v7 Safe Mode and VM New Cluster Re-Attach Error

We had an SBS v7 server setup that we had initially set up on a Hyper-V cluster here in the shop. While we ended up flattening and rebuilding the cluster we left the logical disk containing the SBS v7 OS VHD alone to reattach to a new cluster.

We just finished booting that SBS v7 VM up and ended up with a strangely stalled OS after logging on. For some strange reason Windows Explorer and thus the desktop would not start.

So, we have booted into SBS v7’s Safe Mode:

image

To check on our network settings:

image

Which sent up the following when we set the correct IP address:

image

Microsoft TCP/IP

The IP address 192.168.40.254 you have entered for this network adapter is already assigned to another adapter (Microsoft Virtual Machine Bus Network Adapter) which is no longer present in the computer. . . Do you want to remove the static IP configuration for the absent adapter?

We clicked the Yes button.

So, as long as the new settings have taken the VM should boot into the OS and hopefully allow us to run the Fix My Network Wizard (FMNW) which will clean up the GUID associated with the previous vNIC.

When the server came up this is what we found in the NIC’s IPv4 properties:

image

Note the missing Gateway setting.

This is what the IPConfig /all looked like:

image

Note the 169.254.142.5 address for the IP instead of the 192.168.40.254 IP address indicated in IPv4 properties. So, we still had no network connectivity happening as we also have a Windows 7 Enterprise x64 VM sitting on the same isolated VLAN.

We ran the Internet Address Wizard to see if we could reseat the IP address configuration. Now, we do not have the appropriate VLAN settings in our Cisco SA520-K9 Security Appliance to allow for communication between the SBS v7 VM and the Internet yet but we will soon. So, we ignored the Router Not Found error and ended up with the correct IP address setup.

We also used our Hardware Independent Restore (previous blog post) methodology to clean up the previous NIC’s GUID.

Once we had completed the above and ran the FMNW we saw the following potential network issues:

image

The results were in:

image

Dive into the logs and we found:

image

So, we verified the settings once again for the vNIC and rebooted the server which came back with:

image

Another 169.254.142.5 IP address. :(

Yet, this is what we saw in the NIC’s IPv4 properties:

image

In the registry editor under the NIC’s GUID we see:

image

The IPAddress setting is blank yet our own SBS v7 IP address is not:

image

So, we set the IP address into the registry manually but the NIC’s IPv4 status still showed a 169 address. We then checked the IPv4 properties for the NIC and it had the wrong subnet setting (255.255.255.255). We reconfigured that one and ended up with the following:

image

Note that now we see both IP addresses!

We restarted the DHCP service to see if it would at least start. It did and we were able to receive an IP address for our Windows 7 Enterprise VM:

image

We rebooted the VM to see if the IPv4 settings would stick.

image

They seemingly did:

image

Somehow, this process did not turn out to be as simple as we had hoped.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Monday, 4 October 2010

Key Hyper-V Role and Hyper-V Server 2008 R2 Updates

When putting a new Hyper-V R2 based server into production, there are a few updates that should be applied prior to bringing that new box online.

  1. MS KB2264080: An update rollup package for the Hyper-V role in Windows Server 2008 R2: August 24, 2010
  2. MS KB975354: A Hyper-V update rollup package is available for a computer that is running Windows Server 2008 R2
  3. MS KB974909: The network connection of a running Hyper-V virtual machine is lost under heavy outgoing network traffic on a Windows Server 2008 R2-based computer

Once the updates have been completed we reboot the Hyper-V box prior to beginning our configuration steps.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Intel Modular Server – MPIO Driver Install Requires Second Reboot

When we are in the process of standing up a new Hyper-V Server 2008 R2 cluster node on the Intel Modular Server we walk through an initial set of OS preparation steps.

One is to install the Intel MPIO driver.

When we do, once the compute module has completed its reboot it will more than likely request another reboot:

image

It’s important to note that the reboot request dialogue box may not show up right away depending on the CPU configuration in the compute modules.

After installing the MPIO driver and logging in once the compute module reboot cycle finishes, give the OS some time to process the changes that have been made. The reboot request should come up then.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Intel DX38BT to DP55KG Caveat – Activate Again

Our main office system decided to die this morning. It has been behaving a little on the strange side with network related communications becoming somewhat spotty. The Outlook connection seemed to receive the quickest impact from whatever was going flaky.

We had ordered in an Intel DP55KG, Intel i7-875K, and a CoolerMaster v8 CPU cooler early last month for the purpose of swapping out the system’s DX38BT, QX9650 C2 Extreme, and Zalman CPU cooler. There never seemed to be enough time to do the swap.

Well, this morning’s death made the swap a necessity.

The component swap went painlessly. After running the Intel PROSet driver update, a chipset update, and a few “New Hardware Found” dialogues and reboots the system came up flawlessly. The dual 80GB X25-M SSDs in a RAID 0 stripe were picked up by the newer version on board software RAID without an issue too.

Windows 7 did not ask to be re-activated as we are running Windows 7 Enterprise x64 throughout our organization.

But, Office 2010 Professional Plus (Open Value) and Adobe Design Suite Premium CS3 both requested to be activated again:

image

image

This hardware swap experience sure contrasts to how things were five, ten, or more years ago. In years past we would be hard pressed to save the OS and applications if we needed to change out the motherboard.

We have come a long way indeed.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Friday, 1 October 2010

Quick IE Search Tips: Blog & MSFT KB Examples

This neat tip comes originally from Mariette Knap which we have modified for our own purposes.

After merging the above registry file we may need to restart all IE session for the change to take.

So, just what does the above do?

Well, let’s say we need to get to the Hyper-V Nehalem hotfix page really quick. Since we know the KB number off by heart we type the following in IE’s address bar:

image

Once we hit the Go arrow or Enter we end up at:

image

Okay, we now have quick access to Microsoft Knowledgebase articles that we know the article number for.

Now, we search our own blog _a lot_ as it is a knowledgebase for us too. Thus, we would love to see:

image

Give us:

image

After tweaking the registry entry a little we figured out how to get the above search results by typing the keyword “mblog” and our search terms.

The registry file can be found here:

Here are a couple screenshots of the registry settings:

Microsoft Knowledgebase Quick Search

image

MPECS Inc. Site:blog.mpecsinc.ca Search

image

These little IE tweaks will save us a huge chunk of time!

Susan Bradley also pointed out the following:

The above would have been very handy to get that link into this blog post! :)

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Thursday, 30 September 2010

Integrating An Intel RAID RS2BL040 Battery Backup AXXRSBBU7 With An Intel Server System SR1630HGPRX

The Intel Server System SR1630HGPRX has a spot on one side of the chassis to mount the Intel RAID Controller’s RAID Smart Battery.

Having the battery unit mounted elsewhere in the chassis is a good idea since having it mounted on the RAID controller itself causes an obstruction to the air flowing towards the RAID controller’s processor heatsink.

Tray Mounting

The plastic tray was a bit of a bear to mount in place:

image

We had to slip the guides in onto the high points of the mounting slot and somehow pivot it into the low point with a good amount of effort required to get the locking mechanism to snap in place. The lock is just above the white plastic zip tie in the above screenshot.

Note the star shaped pin near the bottom right hand side of the tray. One would initially gather that it was meant to guide the battery backup’s PCB board into the proper place. Especially since there looks to be a hole in the PCB board just for that purpose.

In fact, it is not a guide but a stand-off to prevent the PCB board from being pushed too far into the tray. Keep this in mind when mounting the battery and PCB.

Another catch to getting the battery/PCB in is in fact the catches themselves. There is one on either side of the tray’s lock. They provide a significant amount of resistance to getting the PCB to set in place. We needed to be mindful of just how much they were being pulled back while trying to slip the PCB into place.

And one more thing when it comes to the tray and batter/PCB combination, there is a requirement for the battery to sit above the PCB in order for the PCB to catch under the two mounting clips on the tray. The PCB clip that holds the battery down looks large enough to prevent this, but there is enough flex in the PCB itself to get things into place.

All in all, this is one snug fitting trio.

image

Remote PCB and RAID Controller

Once we ran the cable from the battery backup to the RAID controller, we needed to install a small daughter card onto the RAID controller itself.

image

The daughter card, shown above, has the socket that connects to the RAID controller as well as the black pivot pin that is used to set the mounting screw into on the RAID controller. The pivot pin is shown in the correct location above. We needed to loosen the screw on the daughter card and rotate the pivot pin into the correct location prior to installing it onto the RAID controller.

The daughter card installed:

image

After installing the power cable the RAID controller was connected to the PCI-E riser and finally installed in the system.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Wednesday, 29 September 2010

Can’t Download Hyper-V Update Rollup Package 2264080 from Update Catalogue

We saw this update go by on one of our freshly installed Hyper-V Server 2008 R2 nodes:

Now, because the update is available through MU (Microsoft Update), we need to go to the Windows Update Catalogue site to download it separately.

Note that an ActiveX component will need to be installed in the browser in order for the site to work.

image

We input the KB number in the search and get the following result:

image

Click on the view basket (1) link to download the update or updates if additional ones were selected.

image

In our case, we ran Internet Explorer 32-bit as a Standard User on Windows 7 Enterprise x64.

After clicking the Download button we should have seen the following IE window pop up:

image

But, we did not. We saw a similar window in the already existing IE session that would not allow us to do anything. We could not choose a folder at all so things came to a full stop.

We ended up trying to start Internet Explorer in an elevated session (Start –> Internet Explorer –> Right click and credential UAC).

Once we did so we were able to choose a directory to drop the update into:

image

But, when we clicked the Continue button:

image

With IE in an elevated session we were still getting stuck.

We ended up logging into one of our Windows 7 VMs using a domain admin account and doing the following to get it to work:

  1. Open Internet Explorer
  2. Navigate to the Windows Update Catalogue site.
  3. Add the site to the Trusted Sites list.
  4. Close IE.
  5. Open IE and navigate to the Catalogue again.
  6. Search for our needed update.
  7. Add it to the Basket.
  8. Click the Download button.
  9. Choose a directory for the download and click Download.
  10. Click Continue for the UAC prompt.
    • This is what was what was causing the hang.
    • image
  11. Click Close.

image

The reason we are downloading the update as opposed to obtaining it through MU is due to the Nehalem hotfix (KB975530) being included along with a fix for running Hyper-V on the new Westmere CPUs. Since we install the Nehalem update by default on all of our Hyper-V deployments we will now use this RU instead.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

IMS – Cluster NIC Setup Worksheet Available

There are a lot of places that we need to pull little bits of information from when preparing to build a cluster on the Intel Modular Server.

When it comes to NIC configuration there are _a lot_ of steps to walk through in order to team them and subsequently configure the needed VLANs on each team.

We have placed a basic worksheet on our Web site that can be downloaded.

image

Please feel free to use this worksheet as a template for your IMS documentation.

The SAS WWM Initiator IDs are required for configuring a Promise VTrak E-Class RAID storage unit with the IMS based cluster.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Tech Days 2010 Edmonton Presentation On Clustering

I will be doing a Tuesday October 5th presentation at the Edmonton Tech Days 2010 event at 15:40Hrs (3:40PM) on Hyper-V Clustering!

image

The slide deck will be minimal with most of the presentation focused on a live Hyper-V Server 2008 R2 cluster running on an Intel Modular Server setup.

Looking for a Tech Days discount code?

  • MVPInvite

The above will discount the entrance cost to $349. Not a bad deal for two days of technical content with no marketing fluff!

Every Tech Days that I have attended have always had bits and bytes to take away. There are lots of ways to get the creative brain juices flowing, this is definitely one of them.

One such bit was fellow MVP Dana Epp’s (his company site) security presentation a few years ago that included a good discussion on using AZMan (John Howard’s explanation) to manage access permissions on a Hyper-V setup.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Tuesday, 28 September 2010

Blog Template Update

Well, after close to four years of using the same template that we modified for our purposes when we first started out on this endeavour, the blog now has an updated template using one of Blogger’s defaults.

The links and such are now where they belong on the left hand side of the page and the restrictions on images seem to no longer be applied. They can actually be _seen_ at whatever size they were screenshot at.

So, enjoy the new look and feel. It should be easier to read for those of us with eyes starting to show their wear and tear too! ;)

And again, thanks to all of you for your ongoing support and contributions to this blog. Without the comments and encouragement over the years the blog would have died a death a long time ago.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Intel Modular Server LUN Copy Feature

The Intel Modular Server has an add-on ability to copy logical disks (LD) from one storage pool to another on the local IMS SAN.

For our in-house cluster we ran a backup of the SBS v7 public beta VM to a VHD located on our data storage server. If we want to start fresh we can restore that SBS v7 OS to a VM in a short amount of time versus doing a fresh Answer File based install.

While we are preparing to stand up a three node cluster on our IMS we are running a test to see if we can keep that SBS v7’s LD available for the soon-to-be cluster.

But, in the meantime we are looking to restructure some of the IMS’s on board SAN storage. So, we are copying that LD from one storage group to another using the LUN Copy feature (MFSLUNCOPY).

image

The whole process took about 25 minutes for the default SBS v7 OS install which is about 20-25 GB in size. The disk is offline at the moment so an accurate number cannot be had. But, the backup VHD file is currently about 20 GB in size.

All of the IMS local storage hard drives with the exception of bays 1 and 2 are 146 GB Seagate 15K Savvio drives. The first two bays have 160 GB X25-M Intel SSDs in them.

Once the copy has completed we can then went on to delete the source LD:

image

Another use for this feature would be to copy an LD of a Windows 7 desktop OS that has been prepared for production use. We would SysPrep the OS and copy that LD to create as many Windows 7 desktop OSs as was needed.

The Microsoft Desktop Deployment Toolkit would be of great benefit if we have a need for more than a few desktop OS deployments.

Further Reading

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

A Few Promise VTrak Performance Graphs

We managed to bring the Promise VTrak demo unit online with a test cluster yesterday.

We set up a set of logical disks on the unit and configured them to connect to various cluster based VMs.

One LD was used as a data partition for an SBS v7 VM while the others were being used as the OS partition for a set of Windows 7 VMs.

Here are a couple of graphs that were imaged at the beginning of the Windows 7 Enterprise x64 OS installs:

image

The above shows the bandwidth being used right when we were starting.

This screenshot shows what the metrics look like over time. When all four Windows 7 desktop OSs were being installed we saw a fairly consistent 145 MB/Second to 165 MB/Second performance for the All Physical Drive Statistics (middle graph).

image

We have since flattened the cluster and set the VTrak back to factory defaults and are running through a fresh cluster build today.

We will then start the VTrak connection process to run through the set up steps in our in-house guide to make sure we have not made any errors.

From there we will begin testing the throughput on the VTrak via the two Intel Modular Server SCMs by running a series of OS installs and large data copies to storage located on the VTrak.

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer

Saturday, 25 September 2010

Distractions Can Be Costly

This post is born out of a bit of frustration . . . but in a good way.

There is a very good reason why we build comprehensive checklists and make sure that we are documenting our progress through any of the procedures from setting up an SBS 2008 or SBS v7 box to building a very complicated Hyper-V cluster.

There are times where total silence, meaning no music, no talking or conversations, or any other forms of distractions are an absolute must.

Today, while running through the set up of a new cluster there were a number of distractions that jumped in within minutes of each other.

The last step accomplished on node 1 of the soon to be 3 node cluster was to set the IP addresses for the various NIC team VLANs with the following step being the setting of the DNS server for each VLAN.

The error made by me was to be running through the steps following our internal cluster set up guide making notes on its structure and such but not actually _checking off each step_ being done.

The phone rang and it was Monique. Then someone had dropped by seeing that the big door was open a bit to allow cool air into the shop. So, after they were dealt with the following looked just fine:

image

That is the default teamed VLAN structure on the node with the blanked IP being our own subnet.

Well, the final step once all of the IP addresses are set into each VLAN is to IPConfig /RegisterDNS to clean out all of the DHCP delivered IP addresses in DNS.

In our SBS v7 DNS the Heartbeat subnet IP showed up but the IP for our own subnet did not for the Management VLAN.

In the end it took about half an hour or more to realize that the step that was missed was to set the DNS server IP address for the Management VLAN.

The cost was my own assumption that the DNS server IPs were set in the first place . . . instead of putting that checkmark at each completed step as I should.

I am the primary reason that checklists have become an important aspect of how we do business and how we build IT solutions.

All it takes is one skipped step to bring things to a screeching halt or crashing down on a production network!

Philip Elder
MPECS Inc.
Microsoft Small Business Specialists
Co-Author: SBS 2008 Blueprint Book

*Our original iMac was stolen (previous blog post). We now have a new MacBook Pro courtesy of Vlad Mazek, owner of OWN.

Windows Live Writer